Immediately after power-up, all three of the green LEDs should illuminate steadily
for several seconds. Then the USB LED shouldash ON three times. Irregularity
of the LED during this LED test may mean there is a problem with the LED itself.
The actual component tests immediately follow the LED tests. A normal (no fault)
result is signaled by aashing of the USB LED, followed by a darkened LED.
If the Self-Test routine traps any component error, then following the LED tests
the Self-Test will halt and the LEDs will continuously signal the error according to
the following table. In the event of any such error signal, contact your dealer for
correction of the faulty unit.
When the DP-301U is powered ON, it also automatically performs a Self-Test
on each of its major components. The final result of the Self-Test is signaled by
the state of the USB LED indicator following the Self-Test. Preliminary to the
actual component tests, the LED indicators are tested to confirm their steady and
ashing operation.
Power ON Self-Test
Every DP-301U has been factory-tested to operate properly.
USB LED
Faulty Component
low speedashing
Need to reload firmware
steady ON
DRAM error
1 long 2 short
1 long 3 short
1 long 5 short
1 long 6 short
1 long 7 short
1 long 11short
LAN I/O base error
LAN memory error
LAN Controller error
Flash Erase/Program error
Flash Protected
Timer INT error
1 long 18 short
USB error
Vedere la pagina 7